EcoElectric Turn Unit
ETR180
Turntable type actuator using EcoElectric Cylinder (180° turn).
By mounting EcoElectric DC Conveyor on EcoElectric Turn Unit, workpiece can flow in a different direction.
[Relevant Product]
ETR90: for 90° turn.
Specs.
Size of main body | W: 799.4 mm L: 524 mm H: 112 mm |
---|---|
Product weight | 82 kg |
Allowable payload (*1) | 600 kg |
Allowable moment (*1) | 55.2 kgm |
Crossed roller bearing rated load | C 50900 N (Dynamic load rating) Co 72200 N (Static load rating) |
Allowable load inertia | 41 kgm2 |
Stopping accuracy | 90° ± 0.1° |
Angular velocity (※2) | 0.393 rad/sec |
90° rotation time (※2) | 4 sec |
(*1) The actual allowable payload and allowable moment need to be determined according to the operating conditions such as the shape of the components attached to the product and the offset position.
(*2) The angular velocity and rotation time are obtained when the speed adjustment channel is set to 5.
Model | ECY40-150 (EcoElectric Cylinder) * w/o brake |
---|---|
Voltage rating | 24VDC ± 10 % |
Output rating | 20 W |
Standby power | 0 W |
Current rating | 1.2 A (rms) |
Maximum current | 2.6 A (rms)(typ.) |
Instantaneous maximum current | 4.0 A (peak) |
Thrust rating | 400 N |
Stroke | 150 mm |
Dedicated controller | Not required |
Connector spec. (EcoElectric Cylinder A) |
M12 connector (male) 4 pins: (1) - (2) 24 V [-90° -> 0°] (3) 0 V (4) 24 V [0° -> -90°] |
Connector spec. (EcoElectric Cylinder B) |
M12 connector (male) 4 pins: (1) - (2) 24 V [0° -> 90°] (3) 0 V (4) 24 V [90° -> 0°] |
Safety Precautions
Please perform risk assessment before use to determine the guarding requirement as it depends on specs and environment of the end user.
Configuration
-
Components
Feature
-
Two-speed control
By installing a sensor, the unit can be controlled to decelerate in the middle of rotation and stop gently.
*Above figure shows an example of -90° turn. -
Speed channel [CH]
Operation speed can be changed by adjusting the speed channel on EcoElectric cylinder (six levels available between CH1 and CH6: do not use CH7 or higher).
Combination example
-
EcoElectric DC Conveyor
By mounting EcoElectric DC Conveyor on top, workpiece can flow in a different direction.
Contact